Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound (if specified)
Moisture Barrier: AL polylaminated tape
Sheath: PE
Armouring: Corrugated steel tapes
Outer sheath: PE, PVC
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound (if specified)
Moisture Barrier: AL polylaminated tape
Sheath: PE
Armouring: Steel wires
Outer sheath: PE, PVC
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound (if specified)
Moisture Barrier: AL polylaminated tape
Sheath: PE
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound (if specified)
Screen / Moisture: AL polylaminated tape
Barrier: Wrapped AL tapes
Sheath: PE
Supporting cord: Steel wires
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound (if specified)
Moisture Barrier: AL polylaminated tape
Sheath: PE
Armouring: Helical steel tapes
Outer sheath: PE, PVC
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound (if specified)
Screen / Moisture: AL polylaminated tape
Barrier: Wrapped AL tapes
Sheath: PE
Conductor: Bronze 1 mm
Insulation: Solid PE
Size: 1 pair
Sheath: PVC
Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Cabling: Pair or quad; unit and sub-unit
Size: 1 to 400 pairs
Screen: Polyester plated AL tape (if specified)
Sheath: PVC
Conductor: Copper 0.4 to 0.9 mm
Insulation: Solid PE
Size: 1 pair or 1 quad
Sheath: PVC (loose tube)
Conductor: Plain copper 0.6 mm
Insulation: Solid PE
Size: 2 to 4 pairs
Strength member: Aramid
Outher Sheath: PE
Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Size: 1 to 7 wires
Conductor: Plain copper 0.4 and 0.5 mm
Insulation: Solid PE or foam skin PE
Cabling: Pair, unit of 8 or 24 pairs, bundles of 24 or 32 pairs
Size: Up to 96 or 128 pairs
Screen / Braid: Polyester plated AL tape and tinned copper wire braid
Outher Sheath: Low Smoke Zero Halogen